Other products by ACS
Model/Series: N-10
BC Part #: 0f28a1c8f8c5
Price: $60.00
Quantity:
 

Description  more details

Workplace Exposure Monitoring

Measurement of personal exposure is very easy. Clip the monitoring badge near the breathing zone of the worker. Record the start time and the stop time of the test on the pouch of the badge and return it to the laboratory for analysis in the mailer provided. The analysis report will show the average concentration of the worker’s personal exposure level.

According to OSHA regulations, each person who uses a toxic gas as a regular part of their job must have their exposure monitored periodically.

Indoor Air Monitoring

Place or hang the badge in your home for 24 hours. Record the start and stop times and send the badge back to the laboratory for analysis in the mailer provided. The analysis report explains if the concentration level of your home is exceeding the exposure limit.

Principle of Operation

Air diffuses through a micro-porous membrane and collects vapor on special prepared adsorbents inside the monitoring badge.

 OSHANIOSHACGIH
TWA (PPM) 25 during time of use    50
STEL/CEIL (PPM)      

 

AKA  Nitrous
 CAS#  10024-97-2
 ANALYTICAL METHOD NIOSH 6600
ABSORBENT  Molecular Sieves
MINIMUM LEVEL OF QUANTITATION 0.3 PPM for 8 Hours
4.8 PPM for 30 Minutes
 RECOMMENDED SAMPLING TIME  Workplace: 30 minutes to 8 hours
Indoor Air: 24 hours – 48 hours
 INTERFERENCES  No interferences are known
 EFFECT OF TEMPERATURE  Less than 10% for each 10°C variation from 24°C
 EFFECT OF HUMIDITY  No effects detected at 30% RH to 92% RH.
 ACCURACY  Meets or exceeds OSHA accuracy requirements of +/- 25%
 STORAGE CONDITIONS  Store at room temperature.
 RECOMMENDED HOLDING TIME Monitors need to be returned to Lab within two weeks after sampling.
Commonly used chemicals used in hospitals

Location/Room

Chemical

Quantity

Description

Operating Room/Labor & Delivery OR’s

Nitrous Oxide

 

Anesthesia Machines

Halogenated Anesthetics

 

Anesthesia Machines

Formaldehyde

 

Frozen Section

Xylene

 

Frozen Section

Glutaraldehyde OR o-Phthaladehyde

 

 

Laboratory

Formaldehyde

 

 

Xylene

 

 

Acetic Acid

 

 

Ethyl Alcohol

 

 

Methyl Alcohol

 

 

Isopropyl Alcohol

 

 

Toluene

 

 

Endoscopy

Nitrous Oxide

 

Anesthesia Machines

Halogenated Anesthetics

 

Anesthesia Machines

Glutaraldehyde OR o-Phthaladehyde

 

Scope Cleaning Room

Acetic Acid/Hydrogen Peroxide

 

Scope Cleaning Room

Isopropyl Alcohol

 

 

Sterilizer Equipment

Ethylene Oxide

 

 

Acetic Acid/Hydrogen Peroxide

 

 

Morgue

Formaldehyde

 

 

Bronchoscopy

Methanol

 

CytoLyt Solution

Formaldehyde

 

 

Glutaraldehyde OR o-Phthaladehyde

 

 

Isopropyl Alcohol

 

 

Ethyl Alcohol

 

 

Urology

Glutaraldehyde OR o-Phthaladehyde

 

 

Formaldehyde

 

 

Isopropyl Alochol

 

 

2-Butoxyethanol

 

 

Hydrogen Peroxide

 

 

Dialysis

Acetic Acid/Hydrogen Peroxide

 

 

Ultrasound

Glutaraldehyde OR o-Phthaladehyde

 

 

Cardiology

Glutaraldehyde OR o-Phthaladehyde

 

 

Sleep Lab

Benzyl Chloride

 

Control 111

Pulmonary

Glutaraldehyde OR o-Phthaladehyde

 

 

Isopropyl Alcohol

 

 



Email A Friend

Send your friend a link to this product.